Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(7)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38612192

RESUMO

This study investigates the effects of zinc (4 wt.%) and severe plastic deformation on the mechanical properties of AZ61 magnesium alloy through the stir-casting process. Severe plastic deformation (Equal Channel Angular Pressing (ECAP)) has been performed followed by T4 heat treatment. The microstructural examinations revealed that the addition of 4 wt.% Zn enhances the uniform distribution of ß-phase, contributing to a more uniformly corroded surface in corrosive environments. Additionally, dynamic recrystallization (DRX) significantly reduces the grain size of as-cast alloys after undergoing ECAP. The attained mechanical properties demonstrate that after a single ECAP pass, AZ61 + 4 wt.% Zn alloy exhibits the highest yield strength (YS), ultimate compression strength (UCS), and hardness. This research highlights the promising potential of AZ61 + 4 wt.% Zn alloy for enhanced mechanical and corrosion-resistant properties, offering valuable insights for applications in diverse engineering fields.

2.
J Funct Biomater ; 15(4)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38667551

RESUMO

The human mandible's cancellous bone, which is characterized by its unique porosity and directional sensitivity to external forces, is crucial for sustaining biting stress. Traditional computer- aided design (CAD) models fail to fully represent the bone's anisotropic structure and thus depend on simple isotropic assumptions. For our research, we use the latest versions of nTOP 4.17.3 and Creo Parametric 8.0 software to make biomimetic Voronoi lattice models that accurately reflect the complex geometry and mechanical properties of trabecular bone. The porosity of human cancellous bone is accurately modeled in this work using biomimetic Voronoi lattice models. The porosities range from 70% to 95%, which can be achieved by changing the pore sizes to 1.0 mm, 1.5 mm, 2.0 mm, and 2.5 mm. Finite element analysis (FEA) was used to examine the displacements, stresses, and strains acting on dental implants with a buttress thread, abutment, retaining screw, and biting load surface. The results show that the Voronoi model accurately depicts the complex anatomy of the trabecular bone in the human jaw, compared to standard solid block models. The ideal pore size for biomimetic Voronoi lattice trabecular bone models is 2 mm, taking in to account both the von Mises stress distribution over the dental implant, screw retention, cortical bone, cancellous bone, and micromotions. This pore size displayed balanced performance by successfully matching natural bone's mechanical characteristics. Advanced FEA improves the biomechanical understanding of how bones and implants interact by creating more accurate models of biological problems and dynamic loading situations. This makes biomechanical engineering better.

3.
Materials (Basel) ; 17(8)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38673196

RESUMO

A new Mg-4Zn X Ti-6Al-4V (TC4, of 0, 1, and 3 wt.%) alloy was successfully fabricated by a simple and low-cost gravity casting method and heat treatment at 150 °C for 24 h. The composite was examined by XRD, uniaxial tests, FESEM/EDS, potentiostat/EIS, and immersion tests for the material's microstructures, mechanical properties, electrochemical characteristics, and corrosion resistance. Experimental results indicate that heat treatment enables the precipitation of Zn along the Mg grain boundaries and drives the co-precipitation of Al around the TC4 particles and nearby grain boundaries. Uniaxial tensile tests reveal that TC4 reinforces the Mg-Zn matrix material with higher elastic modulus, ultimate tensile stress, and toughness. The heat treatment further enhanced these mechanical properties. Electrochemical tests show that 1 wt.% TC4 composite exhibits the highest open circuit potential among all tested samples, which implies the 1 wt.% TC4-added Mg-Zn is better resistant to the oxidation of the essential metals Mg, Zn, and Al. The immersion tests in the HBSS solution further show that the 1 wt.% TC4 composite has the lowest rise of pH values after 14 days, and EDS for the corroded surface signifies that Mg is the main element vulnerable to oxidation by corrosion.

4.
Micromachines (Basel) ; 14(8)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37630077

RESUMO

Pure titanium is limited to be used in biomedical applications due to its lower mechanical strength compared to its alloy counterpart. To enhance its properties and improve medical implants feasibility, advancements in titanium processing technologies are necessary. One such technique is equal-channel angular pressing (ECAP) for its severe plastic deformation (SPD). This study aims to surface modify commercially pure titanium using micro-arc oxidation (MAO) or plasma electrolytic oxidation (PEO) technologies, and mineral solutions containing Ca and P. The composition, metallography, and shape of the changed surface were characterized using X-ray diffraction (XRD), digital optical microscopy (OM), and scanning electron microscope (SEM), respectively. A microhardness test is conducted to assess each sample's mechanical strength. The weight % of Ca and P in the coating was determined using energy dispersive spectroscopy (EDS), and the corrosion resistance was evaluated through potentiodynamic measurement. The behavior of human dental pulp cell and periodontal cell behavior was also studied through a biomedical experiment over a period of 1-, 3-, and 7-days using culture medium, and the cell death and viability can be inferred with the help of enzyme-linked immunosorbent assay (ELISA) since it can detect proteins or biomarkers secreted by cells undergoing apoptosis or necrosis. This study shows that the mechanical grain refinement method and surface modification might improve the mechanical and biomechanical properties of commercially pure (CP) titanium. According to the results of the corrosion loss measurements, 2PassMAO had the lowest corrosion rate, which is determined to be 0.495 mmpy. The electrode potentials for the 1-pass and 2-pass coated samples are 1.44 V and 1.47 V, respectively. This suggests that the coating is highly effective in reducing the corrosion rate of the metallic CP Ti sample. Changes in the grain size and the presence of a high number of grain boundaries have a significant impact on the corrosion resistance of CP Ti. For ECAPED and surface-modified titanium samples in a 3.6% NaCl electrolyte solution, electrochemical impedance spectroscopy (EIS) properties are similar to Nyquist and Bode plot fitting. In light of ISO 10993-5 guidelines for assessing in vitro cytotoxicity, this study contributes valuable insights into pulp and periodontal cell behavior, focusing specifically on material cytotoxicity, a critical factor determined by a 30% decrease in cell viability.

5.
Environ Pollut ; 317: 120578, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36395905

RESUMO

Norfloxacin (NFX) is a commonly consumed synthetic antibiotic drug to cure many adverse infectious diseases of humans worldwide, but their presence in almost all aquatic environments has grown into severe global health concerns. In this study, the power performance of dual-chamber microbial fuel cells (MFCs) with two different types of base anodes (graphite felt and activated carbon cloth) were tested with a coating of NiO/MnO2 for removal of NFX in wastewater. As transition metal oxides have excellent electrochemical stability and a higher specific capacitance, their application in MFC for antibiotic removal and wastewater treatment would be an interesting study. Four different NFX concentrations were studied in two different base material with a coating of NiO/MnO2. Coating was done with 2 step hydro solvothermal method and modified anode surface was characterized by XRD and XPS analyses. Extracellular electron transfer between microorganisms and the modified anode improved significantly as a consequence of reduced internal resistance and a more biocompatible surface as measured by Electroscopy Impedance Spectroscopy (EIS) and polarization curves. NiO/MnO2 coated graphite felt performed 1.2 fold better than the control plain graphite felt. Similar results were found for activated carbon cloth (ACC). Modified ACC performed 1.3 fold better than the control plain ACC.


Assuntos
Fontes de Energia Bioelétrica , Grafite , Purificação da Água , Humanos , Norfloxacino , Grafite/química , Compostos de Manganês , Carvão Vegetal , Óxidos , Eletrodos , Antibacterianos , Eletricidade
6.
Micromachines (Basel) ; 15(1)2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38258140

RESUMO

Blood testing is a crucial application in the field of clinical studies for disease diagnosis and screening, biomarker discovery, organ function assessment, and the personalization of medication. Therefore, it is of the utmost importance to collect precise data in a short time. In this study, we utilized Raman spectroscopy to analyze blood samples for the extraction of comprehensive biological information, including the primary components and compositions present in the blood. Short-wavelength (532 nm green light) Raman scattering spectroscopy was applied for the analysis of the blood samples, plasma, and serum for detection of the biological characteristics in each sample type. Our results indicated that the whole blood had a high hemoglobin content, which suggests that hemoglobin is a major component of blood. The characteristic Raman peaks of hemoglobin were observed at 690, 989, 1015, 1182, 1233, 1315, and 1562-1649 cm-1. Analysis of the plasma and serum samples indicated the presence of ß-carotene, which exhibited characteristic peaks at 1013, 1172, and 1526 cm-1. This novel 3D silicon micro-channel device technology holds immense potential in the field of medical blood testing. It can serve as the basis for the detection of various diseases and biomarkers, providing real-time data to help medical professionals and patients better understand their health conditions. Changes in biological data collected in this manner could potentially be used for clinical diagnosis.

7.
Nanomaterials (Basel) ; 12(24)2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36558307

RESUMO

Halide perovskites-based solar cells are drawing significant attention due to their high efficiency, versatility, and affordable processing. Hence, halide perovskite solar cells have great potential to be commercialized. However, the halide perovskites (HPs) are not stable in an ambient environment. Thus, the instability of the perovskite is an essential issue that needs to be addressed to allow its rapid commercialization. In this work, WS2 nanoparticles (NPs) are successfully implemented on methylammonium lead iodide (MAPbI3) based halide perovskite solar cells. The main role of the WS2 NPs in the halide perovskite solar cells is as stabilizing agent. Here the WS2 NPs act as heat dissipater and charge transfer channels, thus allowing an effective charge separation. The electron extraction by the WS2 NPs from the adjacent MAPbI3 is efficient and results in a higher current density. In addition, the structural analysis of the MAPbI3 films indicates that the WS2 NPs act as nucleation sites, thus promoting the formation of larger grains of MAPbI3. Remarkably, the absorption and shelf life of the MAPbI3 layers have increased by 1.7 and 4.5-fold, respectively. Our results demonstrate a significant improvement in stability and solar cell characteristics. This paves the way for the long-term stabilization of HPs solar cells by the implementation of WS2 NPs.

8.
Micromachines (Basel) ; 13(9)2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36144078

RESUMO

Phase change materials (PCMs) serve as an advantage in thermal energy storage systems utilizing the available sensible and latent heat. The PCMs absorb the thermal energy during the charging process and release it into the environment during the discharging process. Steatite is low cost and eco-friendly, with a thermal stability up to 1000 °C, and it is abundantly available in nature. This study investigates the steatite-paraffin wax-based PCM and the effect on the cyclic loads using a horizontal triplex-tube latent heat energy storage system. The thermal conductivity value of the milled steatite-based PCM composite was 7.7% higher than pure PCM. The PCM with the ball-milled steatite-fabricated composite exhibited better discharging characteristics, increasing the discharge time by 50% more than that of the pure paraffin wax. Moreover, the milled steatite-based PCM outperformed that incorporated with non-milled steatite with paraffin.

9.
Materials (Basel) ; 15(3)2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35160954

RESUMO

Magnesium alloys are attractive for the production of lightweight parts in modern automobile and aerospace industries due to their advanced properties. Their mechanical properties are usually enhanced by the incorporation with reinforcement particles. In the current study, reinforced AZ31 magnesium alloy was fabricated through the addition of bulk Al and the incorporation of SiC nanoparticles using a stir casting process to obtain AZ31-SiC nanocomposites. Scanning electron microscope (SEM) investigations revealed the formation of Mg17Al12 lamellar intermetallic structures and SiC clusters in the nanocomposites. Energy dispersive spectroscopy (EDS) detected the uniform distribution of SiC nanoparticles in the AZ31-SiC nanocomposites. Enhancements in hardness and yield strength (YS) were detected in the fabricated nanocomposites. This behavior was referred to a joint strengthening mechanisms which showed matrix-reinforcement coefficient of thermal expansion (CTE) and elastic modulus mismatches, Orowan strengthening, and load transfer mechanism. The mechanical properties and wear resistance were gradually increased with an increase in SiC content in the nanocomposite. The maximum values were obtained from nanocomposites containing 1 wt% of SiC (AZ31-1SiC). AZ31-1SiC nanocomposite YS and hardness were improved by 27% and 30%, respectively, compared to AZ31 alloy. This nanocomposite also exhibited the highest wear resistance; its wear mass loss and depth of the worn surface decreased by 26% and 15%, respectively, compared to AZ31 alloy.

10.
Chemosphere ; 288(Pt 2): 132446, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34653488

RESUMO

The research on microbial fuel cells (MFCs) is rising tremendously but its commercialization is restricted by several microbiological, material, and economic constraints. Hence, a systematic assessment of the research articles published previously focusing on potential upcoming directions in this field is necessary. A detailed multi-perspective analysis of various techniques for enhancing the efficiency of MFC in terms of electric power production is presented in this paper. A brief discussion on the central aspects of different issues are preceded by an extensive analysis of the strategies that can be introduced to optimize power generation and reduce energy losses. Various applications of MFCs in a broad spectrum ranging from biomedical to underwater monitoring rather than electricity production and wastewater treatment are also presented followed by relevant possible case studies. Mathematical modeling is used to understand the concepts that cannot be understood experimentally. These methods relate electrode geometries to microbiological reactions occurring inside the MFC chamber, which explains the system's behavior and can be improved. Finally, directions for future research in the field of MFCs have been suggested. This article can be beneficial for engineers and researchers concerned about the challenges faced in the application of MFC.


Assuntos
Fontes de Energia Bioelétrica
11.
Chemosphere ; 287(Pt 3): 132248, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34543899

RESUMO

The conflict between climate change and growing global energy demand is an immense sustainability challenge that requires noteworthy scientific and technological developments. Recently the importance of microbial fuel cell (MFC) on this issue has seen profound investigation due to its inherent ability of simultaneous wastewater treatment, and power production. However, the challenges of economy-related manufacturing and operation costs should be lowered to achieve positive field-scale demonstration. Also, a variety of different field deployments will lead to improvisation. Hence, this review article discusses the possibility of integration of MFC technology with various technologies of recent times leading to advanced sustainable MFC technology. Technological innovation in the field of nanotechnology, genetic engineering, additive manufacturing, artificial intelligence, adaptive control, and few other hybrid systems integrated with MFCs is discussed. This comprehensive and state-of-the-art study elaborates hybrid MFCs integrated with various technology and its working principles, modified electrode material, complex and easy to manufacture reactor designs, and the effects of various operating parameters on system performances. Although integrated systems are promising, much future research work is needed to overcome the challenges and commercialize hybrid MFC technology.


Assuntos
Fontes de Energia Bioelétrica , Inteligência Artificial , Eletricidade , Eletrodos , Tecnologia , Águas Residuárias
12.
Inorg Chem ; 60(23): 17986-17996, 2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34747616

RESUMO

Rational design and construction of the finest electrocatalytic materials are important for improving the performance of electrochemical sensors. Spinel bioxides based on cobalt manganate (CoMn2O4) are of particular importance for electrochemical sensors due to their excellent catalytic performance. In this study, three-dimensional CoMn2O4 with the petal-free, flowerlike structure is synthesized by facile hydrothermal and calcination methods for the electrochemical sensing of roxarsone (RXS). The effect of calcination temperature on the characteristics of CoMn2O4 was thoroughly studied by in-depth electron microscopic, spectroscopic, and analytical methods. Compared to previous reports, CoMn2O4-modified screen-printed carbon electrodes display superior performance for the RXS detection, including a wide linear range (0.01-0.84 µM; 0.84-1130 µM), a low limit of detection (0.002 µM), and a high sensitivity (33.13 µA µM-1 cm-2). The remarkable electrocatalytic performance can be attributed to its excellent physical properties, such as good conductivity, hybrid architectures, high specific surface area, and rapid electron transportation. More significantly, the proposed electrochemical sensor presents excellent selectivity, good stability, and high reproducibility. Besides, the detection of RXS in river water samples using the CoMn2O4-based electrochemical sensor shows satisfactory recovery values in the range of 98.00-99.80%. This work opens a new strategy to design an electrocatalyst with the hybrid architecture for high-performance electrochemical sensing.

13.
Sensors (Basel) ; 21(18)2021 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-34577327

RESUMO

Toxic and nontoxic volatile organic compound (VOC) gases are emitted into the atmosphere from certain solids and liquids as a consequence of wastage and some common daily activities. Inhalation of toxic VOCs has an adverse effect on human health, so it is necessary to monitor their concentration in the atmosphere. In this work, we report on the fabrication of inorganic nanotube (INT)-tungsten disulfide, paper-based graphene-PEDOT:PSS sheet and WS2 nanotube-modified conductive paper-based chemiresistors for VOC gas sensing. The WS2 nanotubes were fabricated by a two-step reaction, that is oxide reduction and sulfurization, carried out at 900 °C. The synthesized nanotubes were characterized by FE-SEM, EDS, XRD, Raman spectroscopy, and TEM. The synthesized nanotubes were 206-267 nm in diameter. The FE-SEM results show the length of the nanotubes to be 4.5-8 µm. The graphene-PEDOT:PSS hybrid conductive paper sheet was fabricated by a continuous coating process. Then, WS2 nanotubes were drop-cast onto conductive paper for fabrication of the chemiresistors. The feasibility and sensitivity of the WS2 nanotube-modified paper-based chemiresistor were tested in four VOC gases at different concentrations at room temperature (RT). Experimental results show the proposed sensor to be more sensitive to butanol gas when the concentration ranges from 50 to 1000 ppm. The limit of detection (LOD) of this chemiresistor for butanol gas was 44.92 ppm. The WS2 nanotube-modified paper-based chemiresistor exhibits good potential as a VOC sensor with the advantages of flexibility, easy fabrication, and low fabrication cost.


Assuntos
Nanotubos , Compostos Orgânicos Voláteis , Dissulfetos , Humanos , Limite de Detecção , Tungstênio
15.
Dalton Trans ; 50(21): 7212-7222, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34075924

RESUMO

Developing a non-precious metal electrocatalyst for the oxygen evolution reaction (OER) and oxygen reduction reaction (ORR) is desirable for low-cost energy conversion devices. Herein, we designed and developed a new class of layered cation ordered single perovskite oxides (Pr0.9Ca0.1Co0.8Fe0.2O3-δ) with an optimum ratio of the Co4+/Co3+ oxidation state and oxygen vacancy for oxygen electrode reactions. Catalytic activities are investigated as a function of electronic structure and surface composition. A moderate amount of Ca and Fe dopants keeps the B-site Co cations at a higher oxidation state (Co4+) and generates a vast amount of an oxygen defect rich structure. The improved performance in the ORR and OER is explained by the increase in the sites of Co4+ cations, a state responsible for enhanced catalytic activity. A hypothesis for how doped Ca fraction affects the adsorbed oxygen species and contributes to catalytic activity is discussed. This work sheds light on the influence of crystal structure on the catalytic property and reports that ORR and OER activities are affected not only by oxygen vacancy concentration but also by the oxidation state of the transition metal in the perovskite oxide.

16.
Materials (Basel) ; 13(12)2020 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-32545601

RESUMO

This paper deals with the tribological study of the laser remelted surfaces of the ECAP-processed AZ61 magnesium alloy and AZ61-Al2O3 metal matrix composite with 10 wt.% addition of Al2O3 nanoparticles. The study included the experimental optimization of the laser surface remelting conditions for the investigated materials by employing a 400 W continual wave fiber laser source. Tribological tests were performed in a conventional "ball-on-disc" configuration with a ceramic ZrO2 ball under a 5 N normal load and a sliding speed of 100 mm/s. The results showed that both the incorporation of Al2O3 nanoparticles and the applied laser treatments led to recognizable improvements in the tribological properties of the studied AZ61-Al2O3 composites in comparison with the reference AZ61 alloy. Thus, the best improvement has been obtained for the laser modified AZ61-10 wt.% Al2O3 nanocomposite showing about a 48% decrease in the specific wear rate compared to the laser untreated AZ61 base material.

17.
Talanta ; 116: 704-11, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24148464

RESUMO

Point-of-care diagnostics (POCD) for blood coagulation benefit patients on-site, but available POCD devices are too expensive to be affordable in many countries. Optically based methodologies are cheap and reliable, and have been exploited in bench-top coagulometers to monitor coagulation with plasma, but not whole blood, which contains cellular components that cause massive interference. However, the POCD testing of whole blood gives a more accurate picture of physiological conditions than does testing plasma. In this study, a portable device for performing the prothrombin time (PT) test was designed, comprising an optical sensor, an electrical processing and control circuit to monitor the optical changes that occurred during the coagulation process in whole blood. The PT was when the slope of the first-order derivative of the coagulation curve, recorded from real-time light transmittance signals, was maximal. The POCD PT testing of 167 samples revealed that 153 (91.6%) were successfully detected and the results were highly consistent with the results of whole blood international normalized ratio (INR) (r=0.985, p<0.001) by the conventional manual method and those of plasma INR (r=0.948, p<0.001) with the ACL TOP 700 bench-top coagulometer (Beckman Colter). Hematological parameters were further analyzed, revealing that fibrinogen titers (p=0.036), red blood cell numbers (p=0.017) and distribution of red cell width (p=0.015) affected the effectiveness of the current POCD PT determination. Furthermore, a highly positive correlation was revealed between fibrinogen titers and the maximum speed of change in transmittance (v/t) (r=0.805, p<0.001), suggesting that fibrinogen might be evaluated simultaneously in this POCD testing. In conclusion, the proposed portable optical-based device performs the highly sensitive and accurate determination of whole blood PT and has commercial potential because of its small volume and low fabrication cost.


Assuntos
Técnicas Biossensoriais/instrumentação , Coagulação Sanguínea , Dispositivos Ópticos , Tempo de Protrombina/instrumentação , Anticoagulantes/química , Ácido Cítrico/química , Contagem de Eritrócitos , Índices de Eritrócitos , Fibrinogênio/química , Humanos , Raios Infravermelhos , Coeficiente Internacional Normatizado , Tempo de Protrombina/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...